| CLEAR
HEIGHT |
Ceiling
height to be 20 feet clear to underside of steel joists;
|
| FLOOR |
Reinforced concrete slab on grade;
|
| STRUCTURE |
Structural
steel framing with open web steel roof joists. All structural steel to receive
one coat of gray oxide primer.
|
| WALLS |
All
exterior walls to be architecturally finished. All interior walls, floors, and
ceilings to be unfinished. Fire rate demising walls to the underside of the steel
roof deck;
|
| WINDOWS |
All
windows to be aluminum framed with double glazed thermopane;
|
| HEATING |
One
rooftop HVAC unit, as per approved plans;
|
| INSULATION |
R20
insulation in the roof, 4-ply asphalt felt and pea gravel roof on metal deck,
as per approved plans;
|
| PLUMBING |
Rough-in
provisions for one (1), 2-piece washroom, one (1) second floor sanitary stack capped at first floor, and one (1) 1" water line included
in the unit, as per approved plans;
|
| POWER |
60
Amps, 600 volts to an unfused disconnect switch;
|
| TELEPHONE |
An
empty conduit to a designated point for telephone, as per approved plans;
|
| SHIPPING |
One
3'-0 X 7'-0" hollow metal frame and steel man door and one 10'-0" X
10'-0" steel insulated overhead drive-in doors, where designated as per per
approved plans;
|
| PARKING |
Fully
paved line parking areas and driveways, in accordance with the approved plans;
|
| EXTERIOR |
Architecturally
controlled exterior colours, materials, signage, landscaping, irrigation, in accordance
with the approved plans;
|